The 1772-LP2 is a legacy 2/20 programmable controller processor with an 8192-word memory size and a configurable data table.
ยี่ห้อ :
PLCส่วนจำนวน :
1772-LP2น้ำหนัก :
Verify from the exact processor labelมิติ :
Confirm chassis fit from the installed 1772 system documentationประเทศต้นกำเนิด :
USAรหัส HS :
Legacy 2/20 Processor Unitคำอธิบาย :
The 1772-LP2 is a legacy 2/20 programmable controller processor with an 8192-word memory size and a configurable data table.Click “+” to expand more specifications.
Source: Official publication 5000-RM004 covers 1772-LP2. Verify the nameplate, electrical configuration, wiring, firmware and saved project before replacement.
1772-LP2 is a legacy 2/20 processor that executes the stored control program, scans configured I/O and manages the application data table.
1772-LP2 has an 8192-word memory size, and the data-table allocation can be configured for the installed application.
1772-LP2 must match the installed chassis, power supply, I/O arrangement, programming equipment and communication-adapter hardware.
1772-LP2 and 1772-LP1 should not be interchanged solely because both belong to the legacy 2/20 platform; the exact catalog number, revision, memory map, program and installed hardware must be verified.
Before replacing 1772-LP2, preserve the controller program, data-table and I/O configuration and record the processor revision and communication settings.
A 1772-LP2 inquiry should include nameplate photographs, quantity, processor revision, chassis and power-supply models, memory and I/O configuration, communication adapters and program-backup status.
Official manufacturer-reference information for the 1772-LP2 Legacy 2/20 Processor Unit.
Official publication 5000-RM004 covers identification, installation, wiring, configuration and operating requirements for this catalog variant.
OFFICIAL MANUALSend the complete model, quantity, nameplate photos and your technical or purchasing question.
Technical statements on this page are limited to official publication 5000-RM004. No third-party product sources were used.
PLC is the product-family reference. 1772-LP2 must be matched to the complete nameplate, electrical configuration, I/O or processor arrangement, firmware, wiring and saved project.
Record the installed controller or base, expansion I/O, network design, firmware and adjacent equipment.
Photograph the chassis, processor position, I/O arrangement, communication adapters and grounding before removal.
Verify the installed chassis power supply, processor revision and all field wiring before energizing.
Do not select a substitute until the exact catalog number, 8192-word memory map, I/O configuration, communication adapter and program backup are confirmed.
Match 1772-LP2 and its complete suffix to the full nameplate and installed-system documentation.
Create a recoverable copy of the controller project and record firmware, communication and I/O parameters before removal.
Record the network or serial protocol, addresses, cables, supply and I/O wiring used by the installed application.
Confirm catalog number, firmware, I/O or processor configuration, ports, power, wiring and project compatibility before commissioning.
A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.
Include the complete part number, quantity and delivery destination.