แบนเนอร์
สินค้า
บ้าน /

ฮันนี่เวลล์

/Honeywell CC-PFB802 51454953-176 Series C FIM8 Fieldbus Interface Module
Honeywell CC-PFB802 51454953-176 Series C FIM8 Fieldbus Interface Module
Honeywell CC-PFB802 51454953-176 Series C FIM8 Fieldbus Interface Module
Honeywell CC-PFB802 51454953-176 Series C FIM8 Fieldbus Interface Module

Honeywell CC-PFB802 51454953-176 Series C FIM8 Fieldbus Interface Module

HONEYWELL · SERIES C FOUNDATION FIELDBUS

CC-PFB802 51454953-176

The CC-PFB802 51454953-176 is Honeywell's conformally coated Series C FOUNDATION Fieldbus Interface Module with eight H1 networks. Confirm the complete model and order number, IOTA, redundancy arrangement and system compatibility before replacement or expansion.

MODELCC-PFB802 51454953-176
BRANDHoneywell
PRODUCT FAMILYSERIES C
PRODUCT TYPEFIM8 FIELDBUS MODULE
MANUFACTURERHoneywell
CONDITION / WARRANTYOriginal New · One-Year Warranty
ISO CERTIFICATIONISO-Certified Product
VERIFICATION● Product photos and videos provided after inquiry
REQUEST A QUOTE
MODEL SEARCHFind a specific part numberOpen the best-matched Moore Automation product page directly.
HONEYWELL ● SERIES C FIM8
HONEYWELL SERIES C FOUNDATION FIELDBUS

CC-PFB802 51454953-176

8 H1 NETWORKS · 31.25 KBPS · CONFORMALLY COATED

FOUNDATION FIELDBUS INTERFACE MODULE · FIM8

MODULE ROLE
CC-PFB802 51454953-176 is a Honeywell Series C FOUNDATION Fieldbus Interface Module with eight H1 networks. It connects H1 fieldbus segments to Experion PKS control systems and supports non-redundant or redundant configurations.
CONFIGURATION NOTE
For CC-PFB802 51454953-176, confirm the complete catalog number, CC-TFB811 IOTA, redundancy arrangement, H1 segment design, system release and installed module compatibility before replacement.
👩‍💼
WANT THE BEST PRICE?
Frida
Sales Leader 🏆
EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
CATALOG IDENTITY

Exact model and supplied order-number identification

CC-PFB802
Exact modelSeries C FIM8 Fieldbus Interface Module
51454953-176
Supplied order numberUse this complete order number for compatibility and replacement checks
MANUFACTURER-REFERENCE CHARACTERISTICS

Technical Specifications

Honeywell Product Information ↗
CC-PFB802 51454953-176 FIM8

Engineering data at a glance

Use Honeywell manufacturer-reference data below to verify the exact FIM8 module before replacement or expansion.

H1 NETWORKS8
LINK SPEED31.25 kbps
POWER DISSIPATION9.5 W
MODULE CURRENT0.380 A @ 25 VDC
Honeywell manufacturer references identify CC-PFB802 as the conformally coated Series C FIM8 module.
FIM8 configuration check Confirm CC-PFB802 51454953-176 against the complete order number, CC-TFB811 IOTA, eight H1 links, redundancy arrangement and Experion system compatibility before ordering or replacement.
GENERAL INFORMATION −
BrandHoneywell
Part numberCC-PFB802 51454953-176
Product typeSeries C FOUNDATION Fieldbus interface module
Product familyExperion PKS · Series C
Intended useFOUNDATION Fieldbus H1 interface
H1 networks8
NETWORK AND CONFIGURATION +
Physical interfaceFOUNDATION Fieldbus H1
H1 link speed31.25 kbps
Supported configurationsNon-redundant or redundant
Compatible IOTACC-TFB811 for FIM8 · 8 links
ELECTRICAL AND STATUS INDICATION +
Module current0.380 A @ 25 VDC
Power dissipation9.5 W
Module indicators24 V power · module status · FTE status
IOTA indicators8 H1 link status LEDs · one per link
Front displayModule and link state
INSTALLATION AND INTERFACE +
Link connectionH1 connectors on the IOTA
ConstructionSeries C module · conformally coated
ESD referenceIEC 1000-4-2:1995
System integrationExperion PKS · C300 · ACE
Official source: Honeywell identifies CC-PFB802 as the Series C FIM8 with eight 31.25 kbps H1 networks.
FAQ

Questions Buyers Ask Most

What system role does CC-PFB802 51454953-176 perform?+

CC-PFB802 51454953-176 is a Series C FOUNDATION Fieldbus Interface Module that connects eight H1 networks with Experion PKS control-system architecture.

How many H1 networks can CC-PFB802 51454953-176 support?+

CC-PFB802 51454953-176 supports eight independent H1 networks. Each H1 link operates at 31.25 kbps.

Which physical interface is used by CC-PFB802 51454953-176?+

CC-PFB802 51454953-176 uses the FOUNDATION Fieldbus H1 physical interface, with segment connections provided through the compatible IOTA.

Can CC-PFB802 51454953-176 be installed in a redundant configuration?+

CC-PFB802 51454953-176 can be installed in a redundant configuration. Honeywell documents both non-redundant and redundant FIM8 configurations; verify the matching IOTA and system design.

What electrical values apply to CC-PFB802 51454953-176?+

CC-PFB802 51454953-176 has a documented power dissipation of 9.5 W and module current of 0.380 A at 25 VDC.

How are status conditions shown on CC-PFB802 51454953-176?+

CC-PFB802 51454953-176 provides 24 V power, module and FTE status indications, while the IOTA provides one H1 link-status LED for each of the eight links.

What should be checked before replacing CC-PFB802 51454953-176?+

CC-PFB802 51454953-176 replacement requires the complete model and order number, CC-TFB811 IOTA, redundancy arrangement, H1 segment design, Experion release and quantity. Do not approve substitution by family similarity alone.

CONTACT PRODUCT SPECIALIST

Check your configuration with Frida

Share the complete order number and application details for compatibility, availability and lead-time checking.

CHOOSE A DIRECT CONTACT METHOD
OFFICIAL DATASHEET STATUS

Product Documentation for
CC-PFB802 51454953-176

No direct official Honeywell PDF for the exact complete order number was located in the public document library.

Official datasheet status

The exact model is identified in Honeywell manufacturer references as a Series C FIM8 module. Contact Frida for the correct official document package for your installed system release.

CONTACT FRIDA

Contact to Get Support

Send the complete model, quantity, and your technical or purchasing question.

Technical statements on this page are limited to Honeywell manufacturer references for the CC-PFB802 FIM8.

EXACT PRODUCT IDENTIFICATION

Honeywell CC-PFB802 51454953-176 product identity

Honeywell is the manufacturer; CC-PFB802 is the exact model; 51454953-176 is the supplied order number. Verify the IOTA, redundancy arrangement, H1 segments and system release before replacement.

Honeywell · BRAND
Series C FOUNDATION FieldbusPRODUCT FAMILY
EXACT MODEL

CC-PFB802

Series C FIM8 Fieldbus Interface Module.

SUPPLIED ORDER NUMBER

51454953-176

Complete catalog/order number supplied for this unit.

Replacement check: confirm the CC-TFB811 IOTA, eight H1 links, redundancy arrangement, Experion release and complete order number before replacement.
APPLICATION AREAS

Application map for Honeywell CC-PFB802 51454953-176

FOUNDATION Fieldbus IntegrationConnect eight 31.25 kbps H1 networks to the control-system architecture
Process Control IntegrationIntegrate FOUNDATION Fieldbus devices with Experion PKS, C300 or ACE
APPLICATION CENTER CC-PFB802 Honeywell Series C FIM8 Fieldbus Interface Module
Redundant ArchitectureSupport non-redundant or redundant FIM8 configurations
Smart Device CommunicationsMonitor eight H1 links with one link-status indicator per network
ABOUT MOORE AUTOMATION

A trusted industrial automation sourcing partner

Moore Automation Limited supplies industrial automation spare parts to customers worldwide, with dedicated sourcing, part-number verification, pre-shipment confirmation and responsive sales support.

Global sourcing Pre-shipment verification One-year warranty
SERVICE

Industrial Automation Order Support

A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.

STAGESERVICE ACTIONWHAT WE CHECK OR PROVIDE
01PROCUREMENT
Product SourcingCurrent, hard-to-find and discontinued industrial automation parts.
02VERIFICATION
Part Number ReviewComplete model, suffix, nameplate, visible revision and application details.
03CONFIRMATION
Pre-Shipment CheckModel, label, condition and packaging confirmed with actual photos or video.
04FULFILLMENT
Global Delivery
Worldwide delivery with flexible shipping options. We support door-to-door pickup or delivery to your nominated freight forwarder in China.
DHLFedExUPSTNT
05ASSURANCE
One-Year WarrantyOne-year warranty from delivery for products supplied by Moore Automation.
Warranty Claim Information+
What to provide: If a product-related issue occurs within the warranty period, contact our team and submit one clear, continuous video for review.
✓Complete product and nameplate
✓Power supply and wiring connections
✓Installation and operating conditions
✓Indicator lights, alarms or error messages
✓Clear description of the fault
✓Continuous video showing the issue
Review outcome: If the evidence confirms a covered product fault, Moore Automation will arrange the appropriate warranty solution.
SALES ASSISTANCE

Contact Sales Manager Frida

Include the complete part number, quantity and delivery destination.

EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
Same-brand recommendations

Honeywell Related Models

HONEYWELL ↗Grouped by control, I/O and communication technology
Customers Also Source from Moore

Hot-selling Models

Select a brand to view models
OTHER BRANDSA rotating mix of verified in-site automation models
OTHER BRANDS8768650000Industrial Automation Part
OTHER BRANDS46940C-3Industrial Automation Part
OTHER BRANDS6AV3688-3EH47-0AX0Industrial Automation Part
OTHER BRANDSS-2-TCPUSE-H-Di6Industrial Automation Part
OTHER BRANDSIIR-M-RCT-P1Industrial Automation Part
OTHER BRANDSPA-32IPDA SPA-321PPADAIndustrial Automation Part
OTHER BRANDS11028-00Industrial Automation Part
OTHER BRANDS6AG1222-1BF22-2XB0Industrial Automation Part
OTHER BRANDSC005-M-E2Industrial Automation Part
OTHER BRANDSLV431564Industrial Automation Part
OTHER BRANDS23001-069Industrial Automation Part
OTHER BRANDSSLXPC-P2-MB-BN-12Industrial Automation Part
ฝากข้อความ
หากคุณสนใจในผลิตภัณฑ์ของเราและต้องการทราบรายละเอียดเพิ่มเติม โปรดฝากข้อความไว้ที่นี่ เราจะตอบกลับคุณโดยเร็วที่สุด
  • บมจ
  • ดี.ซี.เอส
  • ทส
  • เอชมิส
สินค้าที่เกี่ยวข้อง