The GE IS200EACFG3A is a G3-version Exciter AC Feedback (EACF) board for the EX2100 excitation-control system
ยี่ห้อ :
GEส่วนจำนวน :
IS200EACFG3Aน้ำหนัก :
2kgมิติ :
30 × 25 × 5cmประเทศต้นกำเนิด :
USAรหัส HS :
8537101190คำอธิบาย :
Exciter AC Feedback Board| CONTACT US Frida Sales Manager | EMAIL FRIDA sales5@mooreplc.com |
| MOBILE / WHATSAPP +86 15359408275 | |
| DIRECT SALES CONTACT |
Product Overview
The GE IS200EACFG3A is a G3-version Exciter AC Feedback (EACF) board for the EX2100 excitation-control system. It measures the exciter power potential transformer (PPT) AC supply through three-phase voltage circuitry and accepts feedback signals from two flux/air-core coils. The board passes these measurement signals to the EX2100 control channels through three 9-pin connectors.
Key Features
- G3 three-phase AC voltage measurement for the EX2100 system.
- Dedicated inputs for two flux/air-core coils.
- Voltage-transformer circuitry produces lower-level feedback signals.
- Three signal connectors serve the M1, M2 and C control channels.
- High-frequency noise suppression at the flux/air-core signal inputs.
Technical Specifications
Parameter
Specification
Three-phase AC input
Up to 1300 V rms +20%
AC input frequency
50/60 Hz
Flux/air-core coil inputs
2
Air-core CT secondary signal
0–0.8 V rms at 50/60 Hz
Control-channel signal connectors
3 × 9-pin connectors
Frequently Asked Questions
Q1. What does IS200EACFG3A measure in the EX2100 system?
It measures the exciter PPT AC supply voltage and accepts current-related feedback from flux/air-core coils.
Q2. What three-phase input rating applies to IS200EACFG3A?
GE specifies the G3 version for a single three-phase input of up to 1300 V rms +20% at 50/60 Hz. The separately documented 1400 V rms rating applies to later G3 revisions, not this G3A model.
Q3. How many flux/air-core coil inputs does IS200EACFG3A provide?
The EACF board has terminals for two coils; GE specifies a 0–0.8 V rms nominal secondary-signal range for air-core current transformers.
Q4. How does IS200EACFG3A deliver its feedback signals to the controllers?
Its voltage and coil-feedback circuits feed three 9-pin connections associated with the M1, M2 and C control channels.
Industries Served
- Steam power — excitation systems for steam-turbine generators.
- Gas-fired power — excitation systems for gas-turbine generators.
- Hydropower — excitation systems for hydro generators.
| Contact us | |
| SALES MANAGER | Frida |
| sales5@mooreplc.com | |
| MOBILE / WHATSAPP | +86 15359408275 |
| Why We Stand Out? | |
|---|---|
|
Parts (wide selection of parts) |
Our product offerings include:DCS, RTU, IPC, Anybus, Industrial Low-Frequency Screens, Human-Machine Interfaces. We provide high-quality parts of various brands, and you can surely find parts that meet your replacement needs. |
| Spare Parts Warehouse | We always keep more than 30,000 different discontinued spare parts for you. Minimize your downtime. |
| Speed | With our established global partner network, we can provide delivery services on a global scale anytime, anywhere. |
| Fast Order Processing | Is there an urgent need for spare parts? Our order fulfillment process is very easy, and can quickly complete the turnover within 24 hours. |
| Expert Team and Solutions | Our experienced professional team leverages years of industry knowledge to provide efficient parts solutions. |
|
Featured Product Lines & Models |
|
|---|---|
| Product Line | Featured Models |
| ABB | |
| ABB Advant OCS and Advant-800xA | D0810, SD831, AI810 TU830V1 |
| ABB Bailey INFI 90 | IMDSO14, IMFEC12, IMDSI22, IMHSS03 |
| ABB H&B Freelance 2000 | AV31 AV 31, LL02 LL 02, RU01 RL 01 |
| ABB Master | DSTX120 5716001-MA, DSTD18P, DSTK183 2639603-BX |
| ABB Operator Panel | PP835A, PP846A 3BSE042238R2 |
| ABB Procontic | CS31, 07KT98, 07SK90R1, 07ZE63R02 |
| ABB Robots | DSQC679, DSQC643, DSQC633, DSQC609 |
| BENTLY NEVADA | |
| 3300 system | 3500/15, 3500/22M, 3500/45, 3500/64M, 3500/94 |
| 3500 system | 3500/12, 3500/20, 3500/46, 3500/50, 3500/65 |
| Proximity Probes | 330130-040-00-00, 330105-02-12-10-02-00, 330130-085-00-00 |
| Proximity Sensor | 330180-50-00, 330180-91-05, 330780-50-00, 330180-91-00 |
| EMERSON | |
| DeltaV | KJ3002X1-BB1 12P068X082, KJ3221X1-BA1 12P2531X132 VE4035S2B1 |
| Fisher | 01984-4282-0001, 01984-2518-0002 |
| Ovation | IC31132G01, 1C31234G01, 5X00058G01, 5X00167G01, 1C31194G01 |
| Rosemount | 2051CD2A02A1AS3I1M5 405PS100N065D3H |
| GE | |
| IS200/DS200 series Excitation system card | IS200WETBH1ABA, IS200VCRCH1BBB, IS200STAIH2ACB, IS200VAICH1DAB, DS200PCCAG10ACB |
| IC693/IC695/IC697/IC698/IC200/IC660/IC670 CPU module | IC693PWR321, IC695CHS012, IC697PWR711M, IC698CPE020, IC200CHS022L |
| Featured Models | ||
|---|---|---|
| GE | ABB | Bently Nevada |
| IC600CB513 | 3ADT313900R1501 SDCS-CON-4 | 330904-00-19-10-01-CN |
| IC600CB516 | 3ADT313900R1001 SDCS-CON-4 | 330904-00-20-10-01-CN |
| IC600CB525 | ZINT-241 3AXD50000003291 | 330904-00-21-10-01-CN |
| IC600CB536 | 3BDZ000398R1 RLM01 | 330904-00-22-05-01-CN |
| IC600CB537 | MGC600-CPU | 330904-00-22-10-01-CN |
| IC655ALG516 | 1SAP180100R0001 MC502 B0 | 330910-00-21-05-01-00 |
| IC655ALG566 | PM581-ETH 1SAP140100R0170 | 330910-00-21-05-01-CN |
| IC655ALG567 | DSAB-01C 64630199Q | 330910-00-21-10-01-00 |
| IC655APU500 | 3HNA024966-00103 | 330910-00-21-10-01-CN |
| IC655APU510 | 3HNA029043-001 | 330910-00-23-05-01-00 |
| IC670MDL742 | 3HNA001625-001 | 330101-00-44-10-02-00 |
| IC670TBM001 | 3HAC032595-001 | 330101-00-65-10-11-05 |